Berichtnavigatie

← Oudere berichten

Teardown Isotech Venus dryblock

Geplaatst op 19 december 2016 door schneiderelectronicsrepairdecember 19, 2016

A peltier powered dryblock from Isotech that stopped working. There was no current flowing to the TECs (peltier elements). That can be caused by a dead controller, dead PSU or dead TECs. They should have a very low resistance so that … Lees verder →

Geplaatst in calibratie apparatuur,Diversen | Tags: calibrator,dryblock,electronica,peltier,reparatie,tear down

E&H massflowmeter PCB repair

Geplaatst op 14 oktober 2016 door schneiderelectronicsrepairmei 29, 2017

This one had a few fried resistors due to a short caused by damaged isolation from a wire. I first removed the resistors. The picture above is after cleaning with IPA. The pads are loose but not damaged. The black … Lees verder →

Geplaatst in meetapparatuur,pcb reparatie | Tags: Endress und Hauser,flowmeter,PCB repair,pcb schade,reparatie,schneider

PCB transplantation of a Fluke DMM

Geplaatst op 14 oktober 2016 door schneiderelectronicsrepairmei 29, 2017

    Fluke uses a resistor divider to tell the processor in what position the switch is. It is made from a sort of carbon film. At the picture above you can see it. This meter has also a problem … Lees verder →

Geplaatst in meetapparatuur,pcb reparatie | Tags: Fluke rangeswitch,meetapparatuur,PCB repair,pcb schade,reparatie,schneider

Megger BT-51

Geplaatst op 25 juli 2016 door schneiderelectronicsrepairjuli 25, 2016

This Megger is one that is made to measure milli and micro ohms. It uses a 2A current for this. The meter part uses a ICL7107, a multimeter IC that is around for many years. It is f.i. used in … Lees verder →

Geplaatst in meetapparatuur | Tags: electronica,meetapparatuur,megger,schneider

Electrtechn laboratorium UH28M high voltage tester

Geplaatst op 25 juli 2016 door schneiderelectronicsrepairjuli 25, 2016

This tester is made unchanged for many many years. It can deliver 5kV and do 100mA. This unit was as dead as an instrument can be. The biggest problem was the power supply transformer that was dead. it has several … Lees verder →

Geplaatst in meetapparatuur | Tags: electronica,meetapparatuur,reparatie,schneider

Valhalla 2701C DC calibrator

Geplaatst op 16 mei 2016 door schneiderelectronicsrepairmei 16, 2016

Repairing calibrators is always fun. This one had no output. It has the 120mA option but that was dead too. The fuse was blown, a logic-opto and a p-channel jfet were dead. The IC caps had a very high leakage … Lees verder →

Geplaatst in calibratie apparatuur | Tags: calibrator,meetapparatuur,reparatie,valhalla

Fluke 123 scope meter

Geplaatst op 12 mei 2016 door schneiderelectronicsrepairoktober 16, 2016

A Fluke scopemeter made in 2010. It stopped charching and turning on resulted in a few seconds before it switched off again. A new battery did not solved the problem and that is why it arrived here. According the owner … Lees verder →

Geplaatst in meetapparatuur | Tags: fluke,meetapparateur,meetapparatuur,reparatie,scope-meter

Hameg HM-8118 LCR meter

Geplaatst op 22 april 2016 door schneiderelectronicsrepairoktober 16, 2016

This LCR meter was dead. Hameg was always very helpful in providing manuals.To bad this is not  the case for the newer gear.  This is a very nice LCR meter with a lot of useful functions. This is the power … Lees verder →

Geplaatst in meetapparatuur | Tags: meetapparateur,meetapparatuur,pcb schade,schneider

Behlman BL-1350

Geplaatst op 22 april 2016 door schneiderelectronicsrepairapril 22, 2016

Dit is een Behlman BL1350 1,35kVA AC powersupply. Een erg zwaar apparaat dankzij 2  enorme trafo’s. Deze was gemodificeerd, waarschijnlijk voor een vaste meet opstelling. Het gevolg was dat hij niets meer deed. Dit was gedaan met een extra PCB … Lees verder →

Geplaatst in Diversen | Tags: electronica,schneider

Hameg HMO-3522 oscilloscoop

Geplaatst op 22 maart 2016 door schneiderelectronicsrepairmaart 22, 2016

Deze scoop was door iemand gebruikt gekocht en zou prima werken. Helaas was dat niet het geval en de verkoper reageerde niet meer.  Het ding flitste een keer met wat ledjes en dat was alles. Dit zijn geen apparaten om … Lees verder →

Geplaatst in meetapparatuur | Tags: electronica,Hameg,meetapparatuur,reparatie,schneider,Tektronix oscilloscoop reparatie

Berichtnavigatie

← Oudere berichten
© 2025 - Schneider Electronics Repair Met trots ondersteund door WordPress  Weaver II by WP Weaver
.
↑